CORROSION INHIBITORS |
|---|
| INTRODUCTION
Gases such as oxygen, carbon dioxide, and hydrogen sulfide are corrosive to wellbore tubulars and other metals. These gases may result from treating fluid interaction with formation waters or hydrocarbons, or may be naturally occurring. Messina corrosion inhibitors are formulated to eliminate corrosion problems. |
|---|
Water soluble filming amine type corrosion inhibitor for total protection of tubular goods used in drilling, completion, and many other applications. Product Data Sheet |
Water soluble, filming amine inhibitor for use in protecting against the type of corrosion characteristic seen when using heavy brines in completion and packer fluids. Very effective in most brines. Product Data Sheet |
Three-phase amine inhibitor for protection from H2S, CO2, organic acids, and mineral salts. Miscible in all phases of oil, water, and gas, which is very important to ensure that the fluid plates properly. Product Data Sheet |
Oil soluble, filming amine type inhibitor for sour well surface facility protection from CO2, H2S, chlorides, and organic acid corrosion in tubular goods. Product Data Sheet |
Water soluble inhibitor corrosion control in gas scrubber units. It is Þ typically loaded from 100 - 300 ppm in the scrub liquor. Product Data Sheet |
Filming cationic amine type inhibitor used in drilling, completion, and packer fluids. It is very effective for all water based fluids in providing a long lasting coating to all metal surfaces. OILAID-CI-16 both absorbs and chemically bonds to tubular goods. To treat an entire system, mix one drum of OILAID-CI-16 per 100 bbls of treating fluid. For batch treatments, slug the pipe at 6 hour intervals with 5 to 10 gallons of a 50/50 mixture of OILAID-CI-16/diesel. This mixture can also be sprayed or painted on pipe prior to storage to protect against corrosion from exposure to the elements on the surface. Product Data Sheet |
Liquid oxygen scavenger for corrosion protection from O2. OILAID- CI-41 provides tubular protection against oxygen corrosion in drilling, completion, and oil production systems. OILAID-CI-41 may be added directly to a mud pump suction line with a chemical pump or added to the mud pit near the pump suction. Loadings typically will vary with application and with the amount of oxygen present in the system. An excess of 20-100ppm sulfite is recommended to control oxygen corrosion. OILAID-CI-41 consumption may vary from 5 to 50 gallons per day. Product Data Sheet |
Water soluble, liquid oxygen scavenger for control of corrosion due to oxygen in drilling, completion, and oil production systems. Typically run at 9 ppm in the water to be treated. Product Data Sheet |
Liquid, multi-purpose water-soluble inhibitor which is extremely effective for control of scale, as well as corrosion caused by oxygen, carbon dioxide, or hydrogen sulfide. OILAID-CI-42 may be applied to packer fluids, workover fluids, fracturing fluids, kill water, or cementing prepad operations. It forms a thin molecular film on all metal surfaces to control corrosion from carbon dioxide, hydrogen sulfide, and oxygen. OILAID-CI-42 employs a sulfite-type oxygen scavenger for oxygen control in tubular goods of drilling, completion fluids, and oil production systems. Carbonate and sulfate scale is controlled with a phosphonate-type inhibitor incorporated in this product. OILAID-CI-42 may also be used in water-based fracturing fluid pads to control corrosion to wells producing water. Loadings depend on the amount and type of problem. For continuous corrosion control, maintain 20 to 100 ppm of OILAID-CI-42. The typical loading range for scale control is: 10 to 20 ppm for calcium carbonate; 2 to 5 ppm for calcium sulfate; and 10 to 30 ppm OILAID- CI-42 should eliminate any barium sulfate scale. Product Data Sheet |
Cationic filming polar organic amine salt and an excellent detergent for use in fresh water and heavy salt brines. OILAID-CI-101 is used in water flood, brine water disposal systems, or in the production wells containing a large water content. OILAID-CI-101 is recommended for pipelines where high water/oil ratios and economics favor a water soluble inhibitor. Loadings vary with source and severity of the corrosion problem and the economics of treating the system. OILAID-CI-101 is recommended for continuous treatment at 5-50 ppm, subject to water concentration and severity of corrosion. |
Liquid polar amine/surfactant blend that forms a protective film on all metal surfaces from chloride and bromide corrosion. OILAID- CI-102 is soluble in fresh water, or sodium, calcium, and potassium salt brines. It is designed to provide protection in high concentration brines used in water-based drilling fluids, packer fluids, and completion fluids. It is completely soluble over a wide temperature range in these fluids. OILAID-CI-102 is typically loaded from 1 to 2% (by vol.), depending on brine concentration and severity of corrosion. |
Organic inhibitor/surfactant for continuous treatment of oil/gas/water flow lines. OILAID-CI-201 is soluble in freshwater and light brines. It provides excellent corrosion protection against carbon dioxide, and hydrogen sulfide. It is recommended for protection during continuous injection of lines carrying water, water-oil, or water-oil-gas. OILAID-CI-201 is a non-foaming material that is especially useful where foaming is to be avoided. It contains a surfactant which prevents emulsions from forming in situations where oil and water are produced together. Normal loadings at temperatures below 125°F (52°C) is 200 ppm. In harsh corrosion environments, higher concentrations may be necessary. Product Data Sheet |
Organic inhibitor/surfactant in alcohol base solvent for treatment in dry gas environments. OILAID-CI-201A is soluble in fresh water and low brines. It provides excellent protection against hydrogen sulfide and carbon dioxide in dry gas environments where a water soluble or alcohol soluble inhibitor is required. This inhibitor is a non- gunking material that is especially formulated for use in a dry environment where many conventional inhibitors will form a viscous gunk. Normal treatment dosage of OILAID-CI-201A in a dry gas pipeline will be to continuously add 1 quart of inhibitor per million cubic feet of produced gas. Product Data Sheet |
Premium filming amine type inhibitor for protection of drill pipe against carbon dioxide, hydrogen sulfide, organic acids, and inorganic salts. OILAID-CI-202 forms a thin but tenaceous uniform film over all pipe surfaces. Normal treatment is one pint to one gallon of OILAID-CI- 202 dispersed in one barrel of fresh water, which is injected into the the mud system as an intermittent slug. All treatments should be best determined by laboratory pilot studies prior to use in the field. Product Data Sheet |
A water soluble amine/quaternary compound corrosion inhibitor for use in water-based packer for drilling fluid systems. OILAID-CI-203 provides protection from carbon dioxide, hydrogen sulfide, and inorganic acids in packer fluids, completion, and drilling fluids. It will tolerate small amounts of dissolved oxygen. OILAID-CI-203 is stable to high temperatures, and will not cause damage when it comes into contact with formation fluids. It is normally recommended at treating rates ranging from 5,000 to 10,000 ppm. Dosage rates are dependent on a number of parameters including temperatures, system solids content, and corrosion damage anticipated. Product Data Sheet |
An oil soluble/water dispersible, multi-functional inhibitor which will film from the water phase. It provides a light, persistent film, but is not a gunking-type inhibitor. OILAID-CI-205 inhibits effectively though the oil phase against hydrogen sulfide, carbon dioxide, organic acids, and inorganic salts in completions fluids, and mud systems. OILADI-CI-205 causes no damage when it comes into contact with producing zones. It is typically loaded at 6-24 L/m3 dispersed in one barrel of water. It can be used in continuous operations, as well as batch treatments, squeeze type treatments in all oil and gas wells, and gas transmission lines. Product Data Sheet |
Oil soluble film forming corrosion inhibitor for protection against hydrogen sulfide, carbon dioxide, and salt water corrosion. OILAID- CI-206 is designed to provide a persistent film not only to the primary working parts of the well, but also throughout the crude gathering lines, storage tanks, and pipelines. OILAID-CI-206 is designed for continuous injection at a rate of 5-25 ppm depending on the severity of the corrosion problem. Product Data Sheet |
An effective oil soluble, water dispersible organic corrosion inhibitor for protection against hydrogen sulfide, carbon dioxide, organic acids, and inorganic salts. It is applicable in completion fluids, mud or production systems, or pipelines. OILAID-CI-207 should be injected continuously into the production system or pipeline using a positive displacement pump. It may be used in squeeze applications by diluting with diesel or kerosene. OILAID-CI-207 causes no damage when it comes in contact with producing formations. Normal concentrations for continuous injection range from 20 to 50 ppm depending on the severity of the corrosion problem. Higher loadings may be necessary during the initial stages of badly or newly corroded systems. After sufficient inhibition has been achieved and a protective film has been established, the loading may be reduced to the previously mentioned loading level of 20 to 50 ppm. Product Data Sheet |
Oil soluble filming amine inhibitor designed for high temperature downhole applications, as well as surface facility protection from CO2, H2S, chlorides, and organic acid corrosion. May be used in continous injection operations, batch mixed, or squeezed. Typical loadings range from 10 - 20 ppm for continous operations, to 1,000 - 10,000 ppm for slug batch treatments. Product Data Sheet |
Surfactant, filming amine type corrosion inhibitor and oxygen scavenger for use in fresh water or brine. It will provide carbon dioxide, hydrogen sulfide, dissolved oxygen, and inorganic salt corrosion protection in packer, completion, and fracturing fluids. Typically loaded at one (1) drum per 100 bbls of treating fluid. Product Data Sheet |
Oil soluble, filming inhibitor for protection in natural gas and gas/condensate handling systems. It shows no tendencies to cause foaming. Normally it is continously injected at a loading range of 5 - 10 ppm, but may also be batch mixed. Product Data Sheet |
Water soluble liquid amine inhibitor designed to reduce corrosion in refinery overhead systems. OILAID-CI-500 also helps reduce fouling of inorganic deposits associated with ammonium-type neutralizers. It protects against corrosion caused by local pitting. This often occurs in overhead exchangers of distillation units where corrosion begins. OILAID-CI-500 enhances the performance of film-forming inhibitors, and in some instances reduces corrosion by itself. In addition, OILAID-CI-500 combines with the often-present mineral acids to form salts which are characteristically more oil soluble than the fouling salts formed when ammonia-based neutralizes are employed. This product is normally run through a positive displacement chemical pump ahead of any existing areas where potential corrosion is a problem. OILAID-CI-500 may also be pumped into the crude charge in order to neutralize any condensate forming on the vessel walls, top trays, top of the atmospheric fractionator, or the overhead condensers. If this method is utilized to neutralize overhead condensers, the top tower temperature must be 270°F or higher. A loading range of 5 to 8 ppm OILAID-CI-500 is usually sufficient to alleviate any problems encountered when the overhead water chloride content is below 100 ppm. Actual loadings should be determined by tests prior to use in the field. |
An oil soluble filming nitrogen condensate inhibitor designed to reduce corrosion from hydrogen chloride salts in distillation column systems. Severe corrosion is possible in this type of system due to the low pH of the initial condensate (usually 1 to 2). OILAID-CI-501 is normally run through a positive displacement pump. It should be continuously injected into the system ahead of any existing areas where potential corrosion is a problem. The dosage of OILAID-CI-Þ 501 necessary for each application will depend on the acid content of the particular system being treated, and whether any other inhibitors are also being employed. It is highly recommended that a total monitoring system be initiated, but a typical dosage of 3 to 5 ppm will normally alleviate any problems encountered. |
High activity inhibitor/biostat for protection against corrosion from hydrogen sulfide and sulfate-reducing bacteria. OILAID-CI0-865 is effective in fresh water or heavy salt brines. OILAID-CI-710 is typically recommended at a rate of 1% (by vol.) based on the amount of treating fluid. Like most cationic materials, OILAID-CI-710 can absorb on metal surfaces, filters or high surface area solids and will tend to flocculate any clay solids suspended in the fluids. Product Data Sheet |
Powder, metallic salt for fresh water and brine fluids used to prevent oxygen corrosion in air, air mist, and air foam drilling operations. OILAID-CI-865 is also effective in aqueous drilling fluids where oxygen, carbon dioxide, and hydrogen sulfide are causing corrosion problems. Recommended loadings should only be made after an extensive study has been completed. Product Data Sheet |
STIMULATION/PRODUCTION CHEMICALS
Send mail to info@messinachemicals.com with
questions or comments about this web site.
Copyright © 2000-2005 Messina Inc.
Last modified: November 15, 2004